On-line Fixed-Bed Microflow Reactor System Equiped with Shimazu GC-2014 (Micro-Scale)

Specifications for GC

Column Oven
Temperature Range(Ambient + 10°C) ~ 400°C (using liquid CO2 gas: -50°C - 400°C)
Dimensions250 (W) x 360 (H) x 175 (D) mm
Oven Capacity15.8L
Temperature AccuracySet value (K) ±1% (calibration at 0.01°C increments)
Temperature Deviation2°C max. (on 200mm dia. circumfrence 30 mm from rear)
Temperature Variation Coefficient0.01°C/°C
Temperature Program StepsUp to 20 (cooling program possible)
Programmed rate setting range-250°C ~ 250°C/min
Total time for all steps9999.99 minutes max.
Linear Heating Range30°C/min up to 150°C
20°C/min up to 250°C
10°C/min up to 380°C
7°C/min up to 400°C (at 25°C ambient temperature)
Cooling Rate300°C ~ 50°C in 6 min max. (at 25°C ambient temperature)
Columns AcceptedCapillary Columns: 2
Packed columns for GC14B: 4 (Glass columns:2)

Sample Injection Unit
Temperature RangeUp to 400°C
Heating Settings1°C steps
No. of units installed simultaneouslyUp to 3 units
Sample injection unit typesDual packed, single packed, split/splitless

 

Carrier Gas Flow Controller
For Packed/Dual
Flow rate setting range0 ~ 100mL/min
Programmable Steps7
Programmed rate setting range-400 ~ 400mL/min
Correction FunctionMaintains column flow rate during column oven heating
For Capillary Split/Splitless 
(Split/Splitless injection mode)
Pressure Setting Range0 ~ 970kPa
Programmable Steps7 (pressure-decreasing program possible)
Programmed rate setting range-400 ~ 400kPa/min
Total flow rate setting range0 ~ 200 mL/min
Correction FunctionMaintains column average linear velocity during column oven heating (for capillary only)
(Pressure mode direct injection)
Pressure Setting Range0 ~ 970kPa/min
Programmable Steps7
Programmed rate setting range-400 ~ 400kPa/min
(Flow-rate mode direct injection)
Flow rate setting range0 ~ 1200mL/min
Programmable Steps7
Programmed rate setting range-400 ~ 400mL/min
Correction FunctionMaintains column average linear velocity during column oven heating (for capillary only)

 

Detectors
Temperature Range400°C max. (FID, TCD, FTD) 350°C max. (ECD, FPD)
Temperature Setting1°C steps
No. of units installed simultaneouslyUp to 4 units (restricted depending on detector type)
Detector TypeFID, TCD, ECD, FPD, FTD for capillary/packed
Flame Ionization Detector (FID)
SystemDual flow rate differential system
Temperature Range400°C max.
Minimum detected quantity3pgC/s (dodecane)
Dynamic Range107
NozzleQuartz glass Standard: for packed, Option: for capillary
Thermal Conductivity Detector (TCD)
SystemDual flow rate differential system
Temperature Range400°C max.
Dynamic Range105
Sensitivity40,000 mV - mL/mg (built-in pre-amplifier, with 10 x amplification)
Electron Capture Detector (ECD)
SystemFixed current system using 63Ni370MBq radiation source
Temperature Range400°C max.
Minimum detected quantity0.1pg/s
Dynamic Range104
Flame Photometric Detector (FPD)
Temperature Range350°C max.
Dynamic RangeP: 104
S: 103
Minimum detected quantityP: 0.5pgP/s (tributyl phosphate)
S: 8pgS/s (dodecane thiol)
Flame Thermionic Detector (FTD)
(Two types, one for capillary and one for packed. The specifications are the same.)
Temperature Range400°C max.
Dynamic RangeN: 103
P: 103
Minimum detected quantityN: 0.4pgN/s (azobenzene)
P: 8pgP/s (malathion)

Display
Dimensions240 x 320 dot graphics display (30 characters x 16 lines)

Dimensions, Weight, Power Requirements (GC main unit)
Dimensions400 (W) x 690 (H) x 607 (D) mm
Weight48 kg (GC-2014AF model)
Power RequirementsAC100V/120V 230V
1800VA (GC-2014AF model) or 
2600VA (GC-2014AF model), 50/60Hz